Fire Safety Obligations API
Is a facility under fire-safety management, fire-risk group 1 or 2, insured, design-appraised, needing a fire team and alarm link (Decree 105/2025)?
For 45 facility types (apartments, schools, hospitals, karaoke, restaurants, shops, hotels, offices, factories and warehouses by fire-hazard class A–E, petrol stations, gas shops, tunnels…) and their size (floors, floor area, business area, volume, seats, pupils, beds, gas stock, voltage, tunnel length), the API applies Decree 105/2025/NĐ-CP as amended by Decree 347/2026/NĐ-CP (from 15 September 2026):
- Appendix I — facility under fire-safety management; Appendix II — facility with fire and explosion risk, group 1 (checked every year) or group 2 (every 2 years, Article 13 as amended); - Appendix VII — compulsory fire and explosion insurance (Article 35); Appendix III — design appraisal by the specialised authority; - Article 20 — an in-house fire and rescue team when 20+ people work there regularly (10 / 15 / 25 members), squads for shifts over 100 people; Article 27 — fire-alarm transmitter connected to the national database by 1 July 2027.
Missing size inputs are listed in missing_inputs instead of being guessed. Results are reference information computed from the official texts cited in legal; they are not legal advice. The reviewed date shows when the rules were last checked.
Markdown · OpenAPI · Postman · llms.txt
Parameters
| Name | In | Type | Required | Default | |
|---|---|---|---|---|---|
type | query | string | yes | Facility type, e.g. karaoke, restaurant, hotel, apartment, factory_c, warehouse_abc, petrol_station (call without it for all 45). | |
floors | query | number | no | Floors of the tallest building. | |
floor_area_m2 | query | number | no | Total floor area, m². | |
business_area_m2 | query | number | no | Area used for business (shops, restaurants, house + business). | |
volume_m3 | query | number | no | Building volume (factories, warehouses). | |
seats | query | number | no | Seats (theatres, stadiums, cultural houses); children, beds for kindergartens / hospitals. | |
gas_kg | query | number | no | Gas stock (gas shops); voltage_kv, length_m, area_ha, construction_class for other types. | |
workers | query | number | no | People working there regularly (fire team); workers_per_shift for squads. |
Example
curl "https://apibox.io.vn/v1/vn-fire-safety?type=karaoke&floors=3&floor_area_m2=400&workers=25" \
-H "Authorization: Bearer YOUR_API_KEY"const res = await fetch('https://apibox.io.vn/v1/vn-fire-safety?type=karaoke&floors=3&floor_area_m2=400&workers=25', {
method: 'GET',
headers: {
Authorization: 'Bearer YOUR_API_KEY',
},
});
const data = await res.json();
console.log(data);import requests
res = requests.get(
"https://apibox.io.vn/v1/vn-fire-safety?type=karaoke&floors=3&floor_area_m2=400&workers=25",
headers={"Authorization": "Bearer YOUR_API_KEY"},
timeout=30,
)
print(res.json())<?php
$ch = curl_init('https://apibox.io.vn/v1/vn-fire-safety?type=karaoke&floors=3&floor_area_m2=400&workers=25');
curl_setopt_array($ch, [
CURLOPT_RETURNTRANSFER => true,
CURLOPT_HTTPHEADER => ['Authorization: Bearer YOUR_API_KEY'],
]);
$response = curl_exec($ch);
print_r(json_decode($response, true));Response
{
"type": "karaoke",
"type_vi": "Thủy cung, karaoke, vũ trường, vui chơi giải trí, biểu diễn nghệ thuật, hoạt động văn hóa khác",
"type_en": "Aquarium, karaoke, dance club, amusement, performance venue",
"managed": {
"required": true,
"basis": [
"floor_area_m2 400 ≥ 50"
],
"ref": "NĐ 105/2025 Phụ lục I mục 8"
},
"fire_explosion_risk": {
"group": 2,
"group_vi": "Nhóm 2",
"basis": [
"floors 3 ≥ 2",
"floor_area_m2 400 ≥ 300"
],
"ref": "NĐ 105/2025 Phụ lục II"
},
"periodic_inspection": {
"every_years": 2,
"by": "Công an (theo phân cấp) hoặc cơ quan chuyên môn về xây dựng do UBND cấp tỉnh phân công",
"ref": "NĐ 105/2025 Điều 13 khoản 2 (sửa đổi bởi NĐ 347/2026)"
},
"compulsory_insurance": {
"required": true,
"basis": [
"floors 3 ≥ 2",
"floor_area_m2 400 ≥ 300"
],
"ref": "NĐ 105/2025 Điều 35, Phụ lục VII (mức phí tối thiểu: Phụ lục VI)",
"note": "Exempt: facilities of the Ministries of Defence / Public Security used for defence and security purposes."
},
"design_appraisal": {
"required": false,
"basis": [],
"ref": "NĐ 105/2025 Phụ lục III (thay thế bởi Phụ lục III NĐ 347/2026 từ 15/9/2026)",
"note": "Works of the list must have their fire-safety design appraised by the specialised authority when built, renovated or changing use; other works: the investor appraises.",
"note_vi": "Công trình thuộc danh mục phải được thẩm định thiết kế về PCCC khi xây dựng mới, cải tạo, thay đổi công năng; công trình khác chủ đầu tư tự chịu trách nhiệm."
},
"fire_alarm_connection": {
"required": true,
"deadline": "2027-07-01",
"note": "Equip and connect a fire-alarm transmitter to the national PCCC & rescue database by 01/7/2027.",
"note_vi": "Trang bị, kết nối thiết bị truyền tin báo cháy với Cơ sở dữ liệu về PCCC và CNCH chậm nhất 01/7/2027.",
"ref": "NĐ 105/2025 Điều 27 khoản 2"
},
"fire_team": {
"required": true,
"kind": "Đội PCCC và CNCH cơ sở",
"min_members": 10,
"leaders": "1 đội trưởng, 1 đội phó",
"ref": "NĐ 105/2025 Điều 20 khoản 2, 5",
"specialised_note": "Industrial zones ≥ 75 ha, oil depots ≥ 100,000 m³, refineries, airports, nuclear plants… must have a specialised (chuyên ngành) team instead — Điều 20 khoản 1."
},
"legal": [
{
"ref": "Luật Phòng cháy, chữa cháy và cứu nạn, cứu hộ số 55/2024/QH15",
"effective_from": "2025-07-01"
},
{
"ref": "Nghị định 105/2025/NĐ-CP quy định chi tiết Luật PCCC và CNCH (Phụ lục I, II, III, VI, VII; Điều 20, 27, 35)",
"effective_from": "2025-07-01",
"url": "https://congbao.chinhphu.vn/cong-bao/cong-bao-so-717-718-ngay-31-05-2025-44911.htm"
},
"…"
],
"disclaimer": "Reference only, not legal advice; check the official text and the competent authority.",
"disclaimer_vi": "Thông tin tham khảo, không phải tư vấn pháp lý; hãy đối chiếu văn bản chính thức và hỏi cơ quan có thẩm quyền.",
"reviewed": "2026-11-15"
}
Use cases
- Tell a karaoke or restaurant owner which fire-safety duties apply
- Flag buildings that must buy compulsory fire insurance
- Screen projects that need fire-safety design appraisal
- Plan fire-alarm connections before the 1/7/2027 deadline
FAQ
Does a 3-floor karaoke of 400 m² need fire insurance?
Yes: karaoke of 2+ floors or 300 m²+ is in Appendix VII and in group 2 of Appendix II (checked every 2 years).
When must a facility set up its own fire team?
Facilities of Appendix I with 20 or more people working regularly; under 20 people, assign fire-safety tasks in writing.
Is a family house covered?
No, unless combined with business (business area 50 m²+). Houses still follow the general fire-safety rules.
Related APIs
JSON Validator
Check JSON syntax with exact line and column of errors, and validate data against a JSON Schema (draft 4, 7, 2019-09 or 2020-12).
{ }JSON Formatter
Pretty print JSON with 0-8 spaces or tabs, minify it, or sort object keys recursively. Syntax errors are reported with line and column.
CSVCSV to JSON
Convert CSV into an array of JSON objects using the header row, with delimiter auto-detection, number and boolean typing, and row-level errors.