# Fire Safety Obligations API

> Is a facility under fire-safety management, fire-risk group 1 or 2, insured, design-appraised, needing a fire team and alarm link (Decree 105/2025)?

- Endpoint: `GET | POST https://apibox.io.vn/v1/vn-fire-safety`
- Category: Data & JSON
- HTML docs: https://apibox.io.vn/docs/vn-fire-safety/ (Vietnamese: https://apibox.io.vn/vi/docs/vn-fire-safety/)
- Online tool: https://apibox.io.vn/tools/vn-fire-safety/
- Authentication: `Authorization: Bearer <API key>` or `X-API-Key: <API key>` (free key: https://apibox.io.vn/dashboard/#signup)

For 45 facility types (apartments, schools, hospitals, karaoke, restaurants, shops, hotels, offices, factories and warehouses by fire-hazard class A–E, petrol stations, gas shops, tunnels…) and their size (floors, floor area, business area, volume, seats, pupils, beds, gas stock, voltage, tunnel length), the API applies Decree 105/2025/NĐ-CP as amended by Decree 347/2026/NĐ-CP (from 15 September 2026):

- Appendix I — facility under fire-safety management; Appendix II — facility with fire and explosion risk, group 1 (checked every year) or group 2 (every 2 years, Article 13 as amended);
- Appendix VII — compulsory fire and explosion insurance (Article 35); Appendix III — design appraisal by the specialised authority;
- Article 20 — an in-house fire and rescue team when 20+ people work there regularly (10 / 15 / 25 members), squads for shifts over 100 people; Article 27 — fire-alarm transmitter connected to the national database by 1 July 2027.

Missing size inputs are listed in `missing_inputs` instead of being guessed. Results are reference information computed from the official texts cited in `legal`; they are not legal advice. The `reviewed` date shows when the rules were last checked.

## Parameters

| Name | In | Type | Required | Default | Description |
|---|---|---|---|---|---|
| `type` | query | string | yes |  | Facility type, e.g. `karaoke`, `restaurant`, `hotel`, `apartment`, `factory_c`, `warehouse_abc`, `petrol_station` (call without it for all 45). |
| `floors` | query | number | no |  | Floors of the tallest building. |
| `floor_area_m2` | query | number | no |  | Total floor area, m². |
| `business_area_m2` | query | number | no |  | Area used for business (shops, restaurants, house + business). |
| `volume_m3` | query | number | no |  | Building volume (factories, warehouses). |
| `seats` | query | number | no |  | Seats (theatres, stadiums, cultural houses); `children`, `beds` for kindergartens / hospitals. |
| `gas_kg` | query | number | no |  | Gas stock (gas shops); `voltage_kv`, `length_m`, `area_ha`, `construction_class` for other types. |
| `workers` | query | number | no |  | People working there regularly (fire team); `workers_per_shift` for squads. |

## Example request

```bash
curl "https://apibox.io.vn/v1/vn-fire-safety?type=karaoke&floors=3&floor_area_m2=400&workers=25" \
  -H "Authorization: Bearer YOUR_API_KEY"
```

## Example response

```json
{
  "type": "karaoke",
  "type_vi": "Thủy cung, karaoke, vũ trường, vui chơi giải trí, biểu diễn nghệ thuật, hoạt động văn hóa khác",
  "type_en": "Aquarium, karaoke, dance club, amusement, performance venue",
  "managed": {
    "required": true,
    "basis": [
      "floor_area_m2 400 ≥ 50"
    ],
    "ref": "NĐ 105/2025 Phụ lục I mục 8"
  },
  "fire_explosion_risk": {
    "group": 2,
    "group_vi": "Nhóm 2",
    "basis": [
      "floors 3 ≥ 2",
      "floor_area_m2 400 ≥ 300"
    ],
    "ref": "NĐ 105/2025 Phụ lục II"
  },
  "periodic_inspection": {
    "every_years": 2,
    "by": "Công an (theo phân cấp) hoặc cơ quan chuyên môn về xây dựng do UBND cấp tỉnh phân công",
    "ref": "NĐ 105/2025 Điều 13 khoản 2 (sửa đổi bởi NĐ 347/2026)"
  },
  "compulsory_insurance": {
    "required": true,
    "basis": [
      "floors 3 ≥ 2",
      "floor_area_m2 400 ≥ 300"
    ],
    "ref": "NĐ 105/2025 Điều 35, Phụ lục VII (mức phí tối thiểu: Phụ lục VI)",
    "note": "Exempt: facilities of the Ministries of Defence / Public Security used for defence and security purposes."
  },
  "design_appraisal": {
    "required": false,
    "basis": [],
    "ref": "NĐ 105/2025 Phụ lục III (thay thế bởi Phụ lục III NĐ 347/2026 từ 15/9/2026)",
    "note": "Works of the list must have their fire-safety design appraised by the specialised authority when built, renovated or changing use; other works: the investor appraises.",
    "note_vi": "Công trình thuộc danh mục phải được thẩm định thiết kế về PCCC khi xây dựng mới, cải tạo, thay đổi công năng; công trình khác chủ đầu tư tự chịu trách nhiệm."
  },
  "fire_alarm_connection": {
    "required": true,
    "deadline": "2027-07-01",
    "note": "Equip and connect a fire-alarm transmitter to the national PCCC & rescue database by 01/7/2027.",
    "note_vi": "Trang bị, kết nối thiết bị truyền tin báo cháy với Cơ sở dữ liệu về PCCC và CNCH chậm nhất 01/7/2027.",
    "ref": "NĐ 105/2025 Điều 27 khoản 2"
  },
  "fire_team": {
    "required": true,
    "kind": "Đội PCCC và CNCH cơ sở",
    "min_members": 10,
    "leaders": "1 đội trưởng, 1 đội phó",
    "ref": "NĐ 105/2025 Điều 20 khoản 2, 5",
    "specialised_note": "Industrial zones ≥ 75 ha, oil depots ≥ 100,000 m³, refineries, airports, nuclear plants… must have a specialised (chuyên ngành) team instead — Điều 20 khoản 1."
  },
  "legal": [
    {
      "ref": "Luật Phòng cháy, chữa cháy và cứu nạn, cứu hộ số 55/2024/QH15",
      "effective_from": "2025-07-01"
    },
    {
      "ref": "Nghị định 105/2025/NĐ-CP quy định chi tiết Luật PCCC và CNCH (Phụ lục I, II, III, VI, VII; Điều 20, 27, 35)",
      "effective_from": "2025-07-01",
      "url": "https://congbao.chinhphu.vn/cong-bao/cong-bao-so-717-718-ngay-31-05-2025-44911.htm"
    },
    "…"
  ],
  "disclaimer": "Reference only, not legal advice; check the official text and the competent authority.",
  "disclaimer_vi": "Thông tin tham khảo, không phải tư vấn pháp lý; hãy đối chiếu văn bản chính thức và hỏi cơ quan có thẩm quyền.",
  "reviewed": "2026-11-15"
}
```

## Use cases

- Tell a karaoke or restaurant owner which fire-safety duties apply
- Flag buildings that must buy compulsory fire insurance
- Screen projects that need fire-safety design appraisal
- Plan fire-alarm connections before the 1/7/2027 deadline

## FAQ

### Does a 3-floor karaoke of 400 m² need fire insurance?

Yes: karaoke of 2+ floors or 300 m²+ is in Appendix VII and in group 2 of Appendix II (checked every 2 years).

### When must a facility set up its own fire team?

Facilities of Appendix I with 20 or more people working regularly; under 20 people, assign fire-safety tasks in writing.

### Is a family house covered?

No, unless combined with business (business area 50 m²+). Houses still follow the general fire-safety rules.