# Vietnam GHG Inventory Calculator API

> Must a Vietnamese facility inventory greenhouse gases (Decree 06/2022, QĐ 42/2026)? Scope 1 and 2 tCO2e with official factors and the 2024 grid factor.

- Endpoint: `GET | POST https://apibox.io.vn/v1/vn-ghg-inventory`
- Category: Data & JSON
- HTML docs: https://apibox.io.vn/docs/vn-ghg-inventory/ (Vietnamese: https://apibox.io.vn/vi/docs/vn-ghg-inventory/)
- Online tool: https://apibox.io.vn/tools/vn-ghg-inventory/
- Authentication: `Authorization: Bearer <API key>` or `X-API-Key: <API key>` (free key: https://apibox.io.vn/dashboard/#signup)

`action=obligation` checks the criteria of Decree 06/2022/NĐ-CP Article 6 (as amended by Decrees 119/2025 and 83/2026): 3,000 tCO2e a year, or 1,000 TOE for thermal power, industry, freight transport and commercial buildings, or 65,000 t of solid waste a year. It returns the duties and deadlines: biennial facility inventory to the province before 31 March (next 31/3/2027), mitigation plan 2026–2030, and for thermal power, steel and cement the verified report before 1 December from 2027 and emission allowances.

`action=calc` (default when `fuels` or `electricity_kwh` is sent) computes scope 1 from fuels (`[{fuel, quantity, unit, sector}]`: diesel, gasoline, fuel_oil, lpg, natural_gas, anthracite, sub_bituminous, kerosene, jet_kerosene, biomass, charcoal… in l, kg, t, GJ, TJ, MWh, MMBtu) with the emission factors of Decision 2626/QĐ-BTNMT and scope 2 from grid electricity with the official grid factor (2024: 0.6187 tCO2/MWh, `grid_year` 2022–2024). GWP sets AR4, AR5 (default) or AR6; TOE is estimated for the obligation test. `custom` lines take your own factors (refrigerants, waste, scope 3).

The facility list of QĐ 42/2026/QĐ-TTg (2,441 facilities, in force 25/9/2026) is the binding test and is not bundled.

## Parameters

| Name | In | Type | Required | Default | Description |
|---|---|---|---|---|---|
| `action` | body|query | string | no |  | obligation, calc or factors. |
| `facility_type` | body|query | string | no | `other` | thermal_power, industrial, freight_transport, commercial_building, solid_waste, other. |
| `annual_emissions_tco2e` | body|query | number | no |  | Annual emissions (obligation test). |
| `energy_toe` | body|query | number | no |  | Annual energy use in TOE. |
| `sector` | body|query | string | no |  | steel, cement or thermal_power for the allowance pilot. |
| `fuels` | body | array | no |  | [{fuel, quantity, unit, sector, ncv_gj_per_t?, density_kg_per_l?}] |
| `electricity_kwh` | body|query | number | no |  | Grid electricity used (kWh). |
| `grid_year` | body|query | number | no | `2024` | Grid factor year (2022–2024) or grid_ef. |
| `gwp` | body|query | string | no | `ar5` | ar4, ar5 or ar6. |
| `custom` | body | array | no |  | [{name, quantity, unit, factor_kgco2e_per_unit, scope}] |

## Example request

```bash
curl -X POST "https://apibox.io.vn/v1/vn-ghg-inventory" \
  -H "Authorization: Bearer YOUR_API_KEY" \
  -H "Content-Type: application/json" \
  -d '{"facility_type":"industrial","fuels":[{"fuel":"diesel","quantity":100000,"unit":"l","sector":"manufacturing"}],"electricity_kwh":5000000}'
```

## Example response

```json
{
  "action": "calc",
  "gwp": "IPCC AR5 (100-year)",
  "totals": {
    "scope1_tco2e": 268.53,
    "scope2_tco2e": 3093.5,
    "scope1_2_tco2e": 3362.03,
    "scope3_tco2e": 0,
    "biogenic_co2_t": 0,
    "fuel_energy_gj": 3612,
    "energy_toe": 857.77
  },
  "lines": [
    {
      "scope": 1,
      "fuel": "diesel",
      "sector": "manufacturing",
      "quantity": 100000,
      "unit": "l",
      "energy_gj": 3612,
      "ef_kg_per_tj": {
        "co2": 74100,
        "ch4": 3,
        "n2o": 0.6
      },
      "co2_t": 267.6492,
      "ch4_kg": 10.836,
      "n2o_kg": 2.1672,
      "tco2e": 268.5269
    },
    {
      "scope": 2,
      "source": "grid electricity (location-based)",
      "quantity": 5000000,
      "unit": "kWh",
      "ef_tco2_per_mwh": 0.6187,
      "grid_year": 2024,
      "tco2e": 3093.5
    }
  ],
  "obligation": {
    "in_scope": true,
    "reasons": [
      "Annual emissions 3362.03 tCO2e ≥ 3,000 (Điều 6 khoản 1)"
    ],
    "quota_sector": false,
    "duties": [
      "listed",
      "inventory",
      "mitigation_plan"
    ]
  },
  "assumptions": [
    "fuels[0]: density 0.84 kg/l assumed for diesel."
  ],
  "reviewed": "2026-11-15",
  "disclaimer": "Reference only, not legal or tax advice; check the official text and your customs / verification body."
}
```

## Use cases

- Check whether a factory falls under the mandatory GHG inventory
- Estimate scope 1 and 2 emissions for an EU customer or an ESG report
- Add a carbon line to an energy management dashboard
- Prepare data for the biennial inventory report (Form 06)

## FAQ

### Which grid emission factor is used?

The latest one published by the ministry: 0.6187 tCO2/MWh for 2024 (Official Letter 11232/BNNMT-BĐKH of 30/9/2026); pass grid_year or grid_ef to change it.

### When is the next inventory report due?

Facilities on the list send the biennial facility report to the provincial People’s Committee before 31 March, next on 31/3/2027.

### Is biomass counted?

Its CH4 and N2O are; its CO2 is reported separately as biogenic and not added to scope 1.