# Vietnam Designated Energy User Check (TOE) API

> Convert electricity and fuels to TOE with the official Vietnamese factors; check the 1,000 / 500 TOE designated-energy-user test and audit duties.

- Endpoint: `GET | POST https://apibox.io.vn/v1/vn-energy-audit`
- Category: Data & JSON
- HTML docs: https://apibox.io.vn/docs/vn-energy-audit/ (Vietnamese: https://apibox.io.vn/vi/docs/vn-energy-audit/)
- Online tool: https://apibox.io.vn/tools/vn-energy-audit/
- Authentication: `Authorization: Bearer <API key>` or `X-API-Key: <API key>` (free key: https://apibox.io.vn/dashboard/#signup)

Send yearly energy use (`electricity_kwh`, `diesel_l` / `diesel_t`, `fuel_oil_t`, `gasoline_l`, `lpg_t`, `natural_gas_m3`, `coal_t` with `coal_grade`, `coke_t`) or a `fuels` array with your own factors or GJ. The API converts to tonnes of oil equivalent with the factors of Circular 02/2014/TT-BCT Appendix I (0.0001543 TOE/kWh, DO 1.02 TOE/t or 0.88 TOE/1,000 l, natural gas 900 TOE per million m³…) and applies Decree 30/2026/ND-CP Article 3: industrial, agricultural and transport facilities from 1,000 TOE a year, buildings (offices, homes, schools, hospitals, hotels, shops…) from 500 TOE.

For a designated energy user it lists the duties of Circular 64/2026/TT-BCT (in force 20/11/2026, replacing Circular 25/2020): consumption report before 15 January, annual plan and report before 30 April, 5-year plan, energy-management model and manager, mandatory energy audit every 3 years (report to the province within 30 days; new entries audit within 1 year). `last_audit_date` gives the next audit date.

The official figure is computed on dataenergy.vn; the province list (approved before 31 March) is the binding test. Reference only.

## Parameters

| Name | In | Type | Required | Default | Description |
|---|---|---|---|---|---|
| `facility_type` | body|query | string | no | `industry` | `industry`, `agriculture`, `transport` (1,000 TOE) or `building` (500 TOE). |
| `electricity_kwh` | body|query | number | no |  | Electricity per year (kWh); also `diesel_l`, `diesel_t`, `fuel_oil_t`, `fuel_oil_l`, `gasoline_l`, `lpg_t`, `natural_gas_m3`, `coal_t` (+ `coal_grade` 1-2 / 3-4 / 5-6), `coke_t`. |
| `fuels` | body | array | no |  | Array of `{fuel, quantity, unit, factor?}`; `unit: "gj"` for any fuel by energy content. |
| `energy_toe` | body|query | number | no |  | Total TOE if already known. |
| `last_audit_date` | body|query | string | no |  | Date of the last energy-audit report (YYYY-MM-DD). |
| `action` | query | string | no |  | `factors` lists the conversion factors. |

## Example request

```bash
curl -X POST "https://apibox.io.vn/v1/vn-energy-audit" \
  -H "Authorization: Bearer YOUR_API_KEY" \
  -H "Content-Type: application/json" \
  -d '{"electricity_kwh":6000000,"diesel_l":100000,"facility_type":"industry"}'
```

## Example response

```json
{
  "facility_type": "industry",
  "energy_toe": 1013.8,
  "energy_gj": 42445.78,
  "threshold_toe": 1000,
  "designated_energy_user": true,
  "margin_toe": 13.8,
  "basis": {
    "vi": "Cơ sở sản xuất công nghiệp, nông nghiệp, đơn vị vận tải tiêu thụ từ 1.000 TOE/năm",
    "ref": "NĐ 30/2026 Điều 3 khoản 1"
  },
  "lines": [
    {
      "fuel": "electricity",
      "fuel_vi": "Điện",
      "quantity": 6000000,
      "unit": "kwh",
      "toe_per_unit": 0.0001543,
      "toe": 925.8
    },
    {
      "fuel": "diesel",
      "fuel_vi": "Dầu DO",
      "quantity": 100000,
      "unit": "l",
      "toe_per_unit": 0.00088,
      "toe": 88
    }
  ],
  "duties": [
    {
      "id": "list",
      "vi": "UBND cấp tỉnh phê duyệt, ban hành danh sách cơ sở sử dụng năng lượng trọng điểm của năm N-1 trước ngày 31/3 năm N; kiểm tra tên cơ sở trong quyết định của tỉnh",
      "ref": "NĐ 30/2026 Điều 4; TT 64/2026 Điều 5",
      "deadline": "2027-03-31"
    },
    {
      "id": "consumption_report",
      "vi": "Báo cáo tình hình tiêu thụ năng lượng năm N-1 tới UBND cấp tỉnh trên dataenergy.vn trước ngày 15/01 năm N (Mẫu 1.1 Phụ lục I)",
      "ref": "TT 64/2026 Điều 4 khoản 4 điểm a",
      "deadline": "2027-01-15"
    }
  ],
  "reviewed": "2026-11-16",
  "disclaimer": "Reference only, not legal advice; check the official text and the competent authority."
}
```

## Use cases

- Check whether a factory or building will appear on the provincial key-energy-user list
- Track the 3-year energy-audit cycle and yearly reporting dates
- Convert fuel bills to TOE for ESG and energy-management dashboards
- Pre-fill the consumption section of the yearly energy report

## FAQ

### Which conversion factors are used?

Circular 02/2014/TT-BCT Appendix I, still in force; send `factor` per line to override (e.g. measured calorific values).

### What changed in 2026?

Decree 30/2026 (21/1/2026) replaced the old decree and Circular 64/2026 replaces Circular 25/2020 from 20/11/2026; the 1,000 / 500 TOE thresholds and the 3-year audit stay.

### Does this cover greenhouse-gas inventory?

No, but 1,000 TOE is also a GHG inventory criterion; use /v1/vn-ghg-inventory for emissions.